Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PNAS Nexus ; 2(11): pgad398, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38034097

RESUMO

Reactive oxygen species (ROS) are central to diverse biological processes through which organisms respond to and interact with their surroundings. Yet, a lack of direct measurements limits our understanding of the distribution of ROS in the ocean. Using a recently developed in situ sensor, we show that deep-sea corals and sponges produce the ROS superoxide, revealing that benthic organisms can be sources and hotspots of ROS production in these environments. These findings confirm previous contentions that extracellular superoxide production by corals can be independent of the activity of photosynthetic symbionts. The discovery of deep-sea corals and sponges as sources of ROS has implications for the physiology and ecology of benthic organisms and introduces a previously overlooked suite of redox reactants at depth.

2.
Environ Sci Technol ; 57(13): 5117-5124, 2023 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-36930700

RESUMO

Coral reefs host some of the highest concentrations of biodiversity and economic value in the oceans, yet these ecosystems are under threat due to climate change and other human impacts. Reef monitoring is routinely used to help prioritize reefs for conservation and evaluate the success of intervention efforts. Reef status and health are most frequently characterized using diver-based surveys, but the inherent limitations of these methods mean there is a growing need for advanced, standardized, and automated reef techniques that capture the complex nature of the ecosystem. Here we draw on experiences from our own interdisciplinary research programs to describe advances in in situ diver-based and autonomous reef monitoring. We present our vision for integrating interdisciplinary measurements for select "case-study" reefs worldwide and for learning patterns within the biological, physical, and chemical reef components and their interactions. Ultimately, these efforts could support the development of a scalable and standardized suite of sensors that capture and relay key data to assist in categorizing reef health. This framework has the potential to provide stakeholders with the information necessary to assess reef health during an unprecedented time of reef change as well as restoration and intervention activities.


Assuntos
Antozoários , Recifes de Corais , Animais , Humanos , Ecossistema , Biodiversidade , Oceanos e Mares , Conservação dos Recursos Naturais/métodos
3.
Sensors (Basel) ; 22(17)2022 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-36081142

RESUMO

Reactive oxygen species (ROS) are key drivers of biogeochemical cycling while also exhibiting both positive and negative effects on marine ecosystem health. However, quantification of the ROS superoxide (O2-) within environmental systems is hindered by its short half-life. Recently, the development of the diver-operated submersible chemiluminescent sensor (DISCO), a submersible, handheld instrument, enabled in situ superoxide measurements in real time within shallow coral reef ecosystems. Here, we present a redesigned and improved instrument, DISCO II. Similar to the previous DISCO, DISCO II is a self-contained, submersible sensor, deployable to 30 m depth and capable of measuring reactive intermediate species in real time. DISCO II is smaller, lighter, lower cost, and more robust than its predecessor. Laboratory validation of DISCO II demonstrated an average limit of detection in natural seawater of 133.1 pM and a percent variance of 0.7%, with stable photo multiplier tube (PMT) counts, internal temperature, and flow rates. DISCO II can also be optimized for diverse environmental conditions by adjustment of the PMT supply voltage and integration time. Field tests showed no drift in the data with a percent variance of 3.0%. Wand tip adaptations allow for in situ calibrations and decay rates of superoxide using a chemical source of superoxide (SOTS-1). Overall, DISCO II is a versatile, user-friendly sensor that enables measurements in diverse environments, thereby improving our understanding of the cycling of reactive intermediates, such as ROS, across various marine ecosystems.


Assuntos
Ecossistema , Superóxidos , Recifes de Corais , Espécies Reativas de Oxigênio , Água do Mar
4.
Sensors (Basel) ; 22(5)2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35270854

RESUMO

Based on knowledge of their production pathways, and limited discrete observations, a variety of short-lived chemical species are inferred to play active roles in chemical cycling in the sea. In some cases, these species may exert a disproportionate impact on marine biogeochemical cycles, affecting the redox state of metal and carbon, and influencing the interaction between organisms and their environment. One such short-lived chemical is superoxide, a reactive oxygen species (ROS), which undergoes a wide range of environmentally important reactions. Yet, due to its fleeting existence which precludes traditional shipboard analyses, superoxide concentrations have never been characterized in the deep sea. To this end, we have developed a submersible oceanic chemiluminescent analyzer of reactive intermediate species (SOLARIS) to enable continuous measurements of superoxide at depth. Fluidic pumps on SOLARIS combine seawater for analysis with reagents in a spiral mixing cell, initiating a chemiluminescent reaction that is monitored by a photomultiplier tube. The superoxide in seawater is then related to the quantity of light produced. Initial field deployments of SOLARIS have revealed high-resolution trends in superoxide throughout the water column. SOLARIS presents the opportunity to constrain the distributions of superoxide, and any number of chemiluminescent species in previously unexplored environments.


Assuntos
Água do Mar , Superóxidos , Carbono , Oxirredução , Espécies Reativas de Oxigênio/metabolismo , Água do Mar/química , Superóxidos/análise , Superóxidos/metabolismo
5.
Appl Opt ; 60(33): 10354-10358, 2021 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-34807043

RESUMO

Sensors that measure dissolved gases directly are needed for environmental, industrial, and biomedical applications. Here we present a hollow core fiber optic sensor capable of measuring dissolved methane gas in liquids using only nanoliters of sample gas. The sensor is based on an anti-resonant hollow core fiber combined with a permeable capillary membrane inlet that extracts gas from the liquid for analysis. Using a small capillary inlet for gas extraction is only possible due to the small amount of sample gas needed for analysis, and it presents new possibilities for dissolved gas analysis in a simple, robust, and compact sensor configuration. We demonstrate the sensing technique using wavelength modulation spectroscopy and measure methane dissolved in water with a 1σ lower detection limit of 230 ppb, a resolution of 45 ppb, and a response time of ∼8min.

6.
Environ Sci Technol ; 53(23): 13850-13858, 2019 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-31660715

RESUMO

Reactive oxygen species (ROS) are produced via various photochemical, abiotic, and biological pathways. The low concentration and short lifetime of the ROS superoxide (O2•-) make it challenging to measure in natural systems. Here, we designed, developed, and validated a DIver-operated Submersible Chemiluminescent sensOr (DISCO), the first handheld submersible chemiluminescent sensor. The fluidic system inside DISCO is controlled by two high-precision pumps that introduce sample water and analytical reagents into a mixing cell. The resultant chemiluminescent signal is quantified by a photomultiplier tube, recorded by a miniature onboard computer and monitored in real time via a handheld underwater LED interface. Components are contained within a pressure-bearing housing (max depth 30 m), and an external battery pack supplies power. Laboratory calibrations with filtered seawater verified instrument stability and precision. Field deployment in Cuban coral reefs quantified background seawater-normalized extracellular superoxide concentrations near coral surfaces (0-173 nM) that varied distinctly with coral species. Observations were consistent with previous similar measurements from aquaria and shallow reefs using a standard benchtop system. In situ quantification of superoxide associated with corals was enabled by DISCO, demonstrating the potential application to other shallow water ecosystems and chemical species.


Assuntos
Antozoários , Animais , Recifes de Corais , Ecossistema , Água do Mar , Superóxidos
7.
Appl Opt ; 56(11): E23-E29, 2017 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-28414338

RESUMO

Methane is a powerful greenhouse gas that has both natural and anthropogenic sources. The ability to measure methane using an integrated path length approach such as an open/long-path length sensor would be beneficial in several environments for examining anthropogenic and natural sources, including tundra landscapes, rivers, lakes, landfills, estuaries, fracking sites, pipelines, and agricultural sites. Here a broadband monolithic distributed feedback-quantum cascade laser array was utilized as the source for an open-path methane sensor. Two telescopes were utilized for the launch (laser source) and receiver (detector) in a bistatic configuration for methane sensing across a 50 m path length. Direct-absorption spectroscopy was utilized with intrapulse tuning. Ambient methane levels were detectable, and an instrument precision of 70 ppb with 100 s averaging and 90 ppb with 10 s averaging was achieved. The sensor system was designed to work "off the grid" and utilizes batteries that are rechargeable with solar panels and wind turbines.

8.
Appl Spectrosc ; 71(5): 996-1003, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27572630

RESUMO

With the recent development of deep ultraviolet (DUV) light emitting diodes (LEDs) comes the possibility of targeting absorption bands of several gases, including sulfur dioxide (SO2). SO2 has strong absorption bands in the 300 nm spectral region. The low cost and small size of DUV LEDs, coupled with their spectral coverage, makes them viable sources for new gas sensors. Here, we demonstrate the capability to use absorption spectroscopy with a balanced detection scheme using a 300 nm DUV LED source for SO2 detection at concentrations ranging from less than 1 ppm to 50 ppm.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...